3nh New Horizontal Type Haze Meter
3nh New Horizontal Type Haze Meter
Product model | YH1810 Color Haze Meter | YH1800 Color Haze Meter | YH1210 Haze Meter |
Geometry | Transmittance: 0/D (parallel illumination, diffuse receiving); Conform to the standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,GB/T 3978,ASTM E308,JIS K7105,JIS K7361,JIS K 7136 | Transmittance: 0/D (parallel illumination, diffuse receiving); Conform to the standards: ASTM D1003/1044, ISO 13468,ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,GB/T 3978, ASTM E308,JIS K7105,JIS K7361,JIS K 7136 | Transmittance: 0/D (parallel illumination, diffuse receiving) in accordance with standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
Characteristic | The instrument can easily realize ASTM D1003 non-compensated method, ISO 13468 compensation method, Full transmittance, haze test, Clarity test. The instrument can accurately collect the transmittance curve of the transmitted sample, and can accurately output various chroma data of the transmitted sample. High hardware configuration, open measurement area, vertical, horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects. | The instrument can easily realize ASTM D1003 non-compensated method, ISO 13468 compensation method, Full transmittance, haze test. The instrument can accurately collect the transmittance curve of the transmitted sample, and can accurately output various chroma data of the transmitted sample. High hardware configuration, open measurement area, vertical, horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects. | The instrument can easily realize ASTM D1003 uncompensated method, ISO 13468 compensation method, Full transmittance, haze test. Open measurement area for vertical and horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects. |
Integrating sphere size | Φ 154 mm | Φ 154 mm | Φ 154 mm |
Light source | 400 ~ 700 nm combined LED light source (wavelength extended is customized) | 400 ~ 700 nm combined LED light source (wavelength extended is customized) | 400 ~ 700 nm combined LED light source |
Spectrophotometric Mode | Concave grating | Concave grating | / |
Sensor | 256 pixel dual array CMOS image sensor | 256 pixel dual array CMOS image sensor | PD array detector, satisfying CIE V(λ)2 degree visual response |
Wavelength range | 400 ~ 700 nm (wavelength scalable customization) | 400 ~ 700 nm (wavelength scalable customization) | / |
Wavelength interval | 10 nm | 10 nm | / |
Half bandwidth | 10 nm | 10 nm | / |
Measurement Range | 0-100% | 0-100% | 0-100% |
Measuring aperture | Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) | Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) | Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) |
Sample size | Thickness less than 105 mm | Thickness less than 105 mm | Thickness less than 105 mm |
Color space | CIE LAB,XYZ,Yxy,LCh,s-RGB,βxy | CIE LAB,XYZ,Yxy,LCh,s-RGB,βxy | / |
Chromatic formula | ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00 | ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00 | / |
Other chromaticity index | Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), Clarity test, WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner Index | Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner Index | Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), |
Observer angle | 2 °/10 ° | 2 °/10 ° | 2 ° |
Light source | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 | D65,A,C |
Display Data | Spectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail result | Spectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail result | Pass/fail result |
Measurement time | About 1.5s | About 1.5s | About 1.5s |
Resolution | 0.01 unit | 0.01 unit | 0.01 unit |
Repeatability | Φ20 mm aperture, less than 0.08 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation) | Φ20 mm aperture, less than 0.08 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation) | Φ20 mm aperture, less than 0.1 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation) |
Inter-instrument Error | Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s) | Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s) | Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s) |
Dimensions | Length X Width X Height = 487X260X298mm | Length X Width X Height = 487X260X298mm | Length X Width X Height = 487X260X298mm |
Weight | Approx. 8.0 kg | Approx. 8.0 kg | Approx. 8.0 kg |
Power supply | 24V 3A , DCpower adapter | 24V 3A , DCpower adapter | 24V 3A , DCpower adapter |
Illuminant Life Span | > 3 million measurements in 5 years | > 3 million measurements in 5 years | > 3 million measurements in 5 years |
Display | TFT True Color 7 inch, Capacitive Touchscreen | TFT True Color 7 inch, Capacitive Touchscreen | TFT True Color 7 inch, Capacitive Touchscreen |
Interface | USB, Print Serial, Bluetooth | USB, Print Serial, Bluetooth | USB, Print Serial |
Data Storage | 5,000 samples, 30,000 samples | 5,000 samples, 20,000 samples | 1,000 samples, 20,000 samples |
Language | Simplified Chinese, Traditional Chinese, English | Simplified Chinese, Traditional Chinese, English | Simplified Chinese, Traditional Chinese, English |
Operating Temperature | 0 to 40 ° C (32 to 104 ° F) | 0 to 40 ° C (32 to 104 ° F) | 0 to 40 ° C (32 to 104 ° F) |
Storage Temperature | - 20 – 50 ° C (-4 – 122 ° F) | - 20 – 50 ° C (-4 – 122 ° F) | - 20 – 50 ° C (-4 – 122 ° F) |
Standard Accessories | Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture | Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture | Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture |
Optional Accessories | Micro printer, Test Fixture, Standard haze sheet, Footswitch | Micro printer, Test Fixture, Standard haze sheet, Footswitch | Micro printer, Test Fixture, Standard haze sheet, Footswitch |
Notes: | Subject to change without notice | Subject to change without notice | Subject to change without notice |