3nh New Vertical Type Haze Meter
Product model | YH1600 Haze Meter | YH1200 Haze Meter | YH1100 Haze Meter | YH1000 Haze Meter |
Geometry | Transmittance: 0/D (parallel illumination, diffuse receiving);Conform to the standards: ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, JIS K 7136 | Transmittance:0/D (Parallel light illumination, diffuse viewing); Conform to the standards:ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 | Transmittance:0/D(Parallel light illumination, diffuse viewing);Conform to the standards:ASTM D1003/1044, ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 | Transmittance:0/D(Parallel light illumination, diffuse viewing);Conform to the standards:ASTM D1003/1044,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
Characteristic | The instrument can easily realize ASTM D1003 non-compensated method, ISO 13468 compensation method, full transmittance, haze test. The instrument can accurately collect the transmittance curve of the transmitted sample, and can accurately output various chroma data of the transmitted sample. High hardware configuration, open measurement area, vertical, horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects. | The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. | The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. | The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. |
Integrating sphere size | Φ 154 mm | Φ154mm | Φ154mm | Φ154mm |
Light source | 400 ~ 700 nm combined LED light source (wavelength scalable customized) | 400nm to 700nm, combined LED light | 400nm to 700nm, combined LED light | 400nm to 700nm, combined LED light |
Spectrophotometric Mode | Concave grating | / | / | / |
Sensor | 256 pixel dual array CMOS image sensor | The PD array detector satisfies CIE V(λ)2 degree visual response | The PD array detector, satisfies CIE V(λ)2 degree visual response | The PD array detector, satisfies CIE V(λ)2 degree visual response |
Wavelength range | 400 ~ 700 nm (wavelength scalable customization) | / | / | / |
Wavelength interval | 10 nm | / | / | / |
Half bandwidth | 10 nm | / | / | / |
Measurement Range | 0-100% | 0~100% | 0~100% | 0~100% |
Measuring aperture | Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) | Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) | Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) | Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) |
Sample size | Thickness less than 170 mm | Thickness <170mm | Thickness <170mm | Thickness<170mm |
Color space | CIE LAB, XYZ, Yxy, LCh, s-RGB, βxy | / | / | / |
Chromatic formula | ΔEab, ΔE94, ΔEcmc (2:1), ΔEcmc (1:1), ΔE00 | / | / | / |
Other chromaticity index | Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner Index | Haze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM) | Haze(ASTM D1003/1044),Transmittance T(ASTM) | Haze(ASTM D1003/1044),Transmittance T(ASTM) |
Observer angle | 2 °/10 ° | 2° | 2° | 2° |
Light source | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 | D65,A,C | D65,A,C | D65,A,C |
Display Data | Spectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail result | PASS/FAIL Result | PASS/FAIL Result | PASS/FAIL Result |
Measurement time | About 1.5s | About1.5s | About1.5s | About1.5s |
Resolution | 0.01 unit | 0.01unit | 0.01unit | 0.01unit |
Repeatability | Φ20 mm aperture, less than 0.08 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation) | Φ20mm,within 0.1 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.) | Φ20mm,within 0.1(After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.) | Φ20mm,within 0.15 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.) |
Inter-instrument Error | Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s) | Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) | Φ20mm,with 0.4(After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) | Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) |
Dimensions | Length * Width * Height = 290*211*511 mm | L*W*H=290X211X511mm | L*W*H=290X211X511mm | L*W*H=290X211X511mm |
Weight | Approx. 7.6 kg | About7.6kg | About7.6kg | About7.6kg |
Power supply | 24 V DC, supplied by 3A power adapter | AC 24V, 3A Power adapter power supply | AC 24V, 3A Power adapter power supply | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | > 3 million measurements in 5 years | 5 years, more than 3 million times measurements | 5 years, more than 3 million times measurements | 5 years, more than 3 million times measurements |
Display | TFT True Color 7 inch, Capacitive Touchscreen | 7-inch TFT color LCD, Capacitive Touch Screen | 7-inch TFT color LCD, Capacitive Touch Screen | 7-inch TFT color LCD, Capacitive Touch Screen |
Interface | USB, Print Serial,Bluetooth | USB, Print serial port | USB, Print serial port | USB, Print serial port |
Data Storage | 5,000 samples, 20,000 samples | Standard 1000 pcs,sample 20000 pcs | Standard 1000 pcs,sample 20000 pcs | Standard 1000 pcs,sample 10000 pcs |
Language | Simplified Chinese, Traditional Chinese, English | Simplified Chinese,Traditional Chinese,English | Simplified Chinese,Traditional Chinese,English | Simplified Chinese,Traditional Chinese,English |
Operating Temperature | 0 to 40 ° C (32 to 104 ° F) | 0~40℃(32~104°F) | 0~40℃(32~104°F) | 0~40℃(32~104°F) |
Storage Temperature | - 20 – 50 ° C (-4 – 122 ° F) | -20~50℃(-4~122°F) | -20~50℃(-4~122°F) | -20~50℃(-4~122°F) |
Standard Accessories | Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture | Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. | Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. | Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. |
Optional Accessories | Micro printer, Test Fixture, Standard Haze Sheet, Footswitch | Micro-printer,Test fixture, standard haze sheet, foot switch | Micro-printer,Test fixture, standard haze sheet, foot switch | Micro-printer,Test fixture, standard haze sheet, foot switch |
Notes: | Subject to change without notice | The specifications are subject to change without notice. | The specifications are subject to change without notice. | The specifications are subject to change without notice. |