3nh ST60 Spectrophotometer (Core Technology) with 4 apertures
Introduction
The twin sister ST series of 3NH TS series is launched grandly, inherits the core technology of large-area array sensor and grating splitting in the field of color detection, and acutely analyzes the strong and weak light in 300-1100nm band. Our TS series has always been imitated, but never surpassed. TS series since its birth has been adhering to the quality first, with the purpose of quality, after years of continuous improvement, we can proudly say: ST series, let the color measurement is very accurate! In the future, 3nh will continue to practice the mission of "specialized and innovation" enterprise and high-tech enterprise, overcome difficulties and continue to innovate on the road of testing instruments, so that our partners can have a wonderful high accuracy and quality measurement instrument.
Spectrophotometer ST60 is a spectrophotometer developed by 3NH TS series core technology, using built-in photodiode array (double 26 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability delta E* AB of ST60 spectrophotometer is easily controlled within 0.025, and the Inter-instrument error delta E* AB is controlled within 0.15, to make the measurement more accurate. And the test data can be used for accurate color analysis and transmission in the laboratory.
Application
Spectrophotometer ST60 is equipped with 4 kinds of measuring apertures, with wider adaptability, accurate color measurement and stable performance. It is used for accurate color measurement and quality control in plastic electronics, paint ink, textile and garment printing and dyeing, printing, ceramics and other industries, and can be used for fluorescent sample measurement.
Features
1. Large area photodiode array (dual 26 arrays) sensor
A larger area of double 26 array sensor, strong light saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, independent core technology, and international standards of the same platform, to achieve complete compatibility.
Model |
ST60 spectrophotometer |
Optical Geometry |
D/8 (diffused illumination, 8-degree viewing angle) |
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source |
|
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 |
|
Characteristic |
Adopt 3nh TS series core technology, 4 measuring apertures for accurate color analysis and transmission in laboratory |
It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement. |
|
Integrating Sphere Size |
Φ40mm |
Light Source |
Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode |
Flat Grating |
Sensor |
Silicon photodiode array (double row 26 groups) |
Wavelength Range |
360~700nm |
Wavelength Interval |
10nm |
Measured Reflectance Range |
0-200% |
Measuring Aperture |
4 apertures: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm; |
Specular Component |
SCI&SCE |
Color Space |
CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99,Munsell(C/2) |
Color Difference Formula |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other Colorimetric Index |
Spectral reflectance,WI(ASTM E313,CIE/ISO, AATCC, Hunter, TaubeBergerStensby), |
YI(ASTM D1925,ASTM 313), |
|
Metamerism Index MI, |
|
Staining Fastness, Color Fastness, Color Strength, Opacity, |
|
8° Glossiness,555 tone classification, Carbon (My,dM), color density CMYK(A,T,E,M), Tint, Munsel chroma index (part of the function is realized by PC software) |
|
Observer Angle |
2°/10° |
Illuminant |
D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30),B,U35,NBF, ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, able to customized light source (total 41 kinds of light source, Partially realize through the PC software /APP software) |
Displayed Data |
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color simulation, Color Offset |
Measuring Time |
About 1.5s |
Repeatability |
Chromaticity value: MAV/SCI, within ΔE*ab 0.025 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) |
|
Inter-instrument Error |
MAV/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
Display Resolution |
0.01 |
Measurement Mode |
Single Measurement, Average Measurement(2-99times) |
Locating Method |
Camera Locating,stabilizer cross position |
Dimension |
L*W*H=129X76X217mm |
Weight |
Approx 600g |
Battery |
Li-ion battery, 8800 measurements within 8 hours |
Illuminant Life Span |
10 years, more than 1.5 million times measurements |
Displayed Data |
3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port |
USB, Bluetooth ® 5.0 |
Data Storage |
Standard 1000 Pcs, Sample 30000 Pcs, APP/PC mass storage |
Software Support |
Andriod,IOS,Windows,Harmony OS,Wechat applets |
Language |
Simplified Chinese, English, traditional Chinese |
Operating Environment |
0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment |
-20~50℃, 0~85%RH (no condensing) |
Standard Accessory |
Power Adapter, USB cable, User Guide, PC Software(Download from office website), White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture |
Optional Accessory |
Micro Printer, Powder Test Box |
Notes |
The specifications are subject to change without notice. |