You Are Here : Home >> Products >> Spectrophotometer >> 3nh ST70 spectrophotometer (Core Technology) with 5 apertures

3nh ST70 spectrophotometer (Core Technology) with 5 apertures

Spectrophotometer ST70 is a spectrophotometer developed by 3NH TS series core technology, using built-in photodiode array (double 32 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability delta E* AB of ST70 spectrophotometer is easily controlled within 0.02, and the Inter-instrument error delta E* AB is controlled within 0.15, to make the measurement more accurate. And the test data can be used for accurate color analysis and transmission in the laboratory.
More Photos:
Date:2022-04-02  Browse:
  • Introduction
  • Product Software

3nh ST70 Spectrophotometer (Core Technology) with 5 apertures

 

Introduction

 

The twin sister ST series of 3NH TS series is launched grandly, inherits the core technology of large-area array sensor and grating splitting in the field of color detection, and acutely analyzes the strong and weak light in 300-1100nm band. Our TS series has always been imitated, but never surpassed. TS series since its birth has been adhering to the quality first, with the purpose of quality, after years of continuous improvement, we can proudly say: ST series, let the color measurement is very accurate! In the future, 3nh will continue to practice the mission of "specialized and innovation" enterprise and high-tech enterprise, overcome difficulties and continue to innovate on the road of testing instruments, so that our partners can have a wonderful high accuracy and quality measurement instrument.

 

Spectrophotometer ST70 is a spectrophotometer developed by 3NH TS series core technology, using built-in photodiode array (double 32 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability delta E* AB of ST70 spectrophotometer is easily controlled within 0.02, and the Inter-instrument error delta E* AB is controlled within 0.15, to make the measurement more accurate. And the test data can be used for accurate color analysis and transmission in the laboratory.

 

Application

 

Spectrophotometer ST70 is equipped with 5 kinds of measuring apertures, with wider adaptability, accurate color measurement and stable performance. It is used for accurate color measurement and quality control in plastic electronics, paint ink, textile and garment printing and dyeing, printing, ceramics and other industries, and can be used for fluorescent sample measurement.

 

Features

 

1. Large area photodiode array (dual 32 arrays) sensor

 

A larger area of double 32 array sensor, strong light saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, independent core technology, and international standards of the same platform, to achieve complete compatibility.

2. Adopt D/8 structure and SCI/SCE mode

 

Spectrophotometer ST70 uses a widely international use D/8 optical structure, SCI/SCE (Specular Component Included/Specular Component Excluded) synthesis technology, support SCI+SCE at the same time fast measurement, test time about 1.5 seconds.

3. Combination of full spectrum LED light source and UV light source

 

The use of 360-780nm full spectrum LED light source ensures sufficient spectral distribution in the visible light range, avoiding the spectral loss of specific bands, strong light will not be saturated, weak light is more sensitive, and fluorescence samples can be easily measured.

4. Equipped with five kinds of measuring apertures to meet the most samples measurement requirements

 

Spectrophotometer ST70 factory standard with 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture,1x3mm tip aperture, a total of five measuring apertures, to meet the measurement needs of most special samples.

5. Camera positioning can clearly observe the measured area

 

The ST70 spectrophotometer has built-in camera. Through the real-time scene-taking of the camera, it can accurately determine whether the measured part of the object is the target center, which improves the measurement efficiency and accuracy.

ST70 Spectrophotometer

6. Non-contact automatic calibration, professional imported white board, more wear-resistant, dirty, stable

7. Place the base safely to ensure that the whiteboard is not dirty.

8. Offer 10 kinds of color measurement space and 41 kinds of observation light source

 

Offer CIE LAB,XYZ,Yxy,LCh,CIE LUV, S-RGB, HunterLab, βxy, DIN Lab99, Munsell(C/2) color spaces, and D65, A, C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30), B, U35, NBF, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, LED-C2, LED-C3, LED-C5. It also can be customized light source (A total of 41 kinds of light source, Partially realize through the PC software /APP software), and can meet the special measurement requirements under different measurement conditions.

COLOR SPACE

9. Many color indexes

 

Spectrophotometer ST70 not only provides the commonly used color measurement, but also provide spectral reflectance, WI (ASTM E313, CIE/ISO, AATCC, Hunter, TaubeBergerStensby), YI (ASTM D1925, ASTM 313), Metamerism index of Mt, Staining Fastness, Color Fastness, Color Strength, Opacity, 8 degree gloss, 555 tone classification, Carbon(My,dM), color density CMYK(A,T,E,M), Tint, Munsel chroma index (part of the function is realized by PC software).

 

10. Excellent instrument errors and repeatability

 

Ensure the consistency of measurement data of multiple equipment, to be used for color matching and accurate color transfer.

11. Support Huawei Harmony OS, Android, IOS, Wechat applets, Windows programs

Specification

 

Model

ST70 spectrophotometer

Optical Geometry

D/8 (diffused illumination, 8-degree viewing angle)

SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source

Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7

Characteristic

Adopt 3nh TS series core technology, 5 measuring apertures for accurate color analysis and transmission in laboratory

It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement.

Integrating Sphere Size

Φ40mm

Light Source

Combined full spectrum LED light source, UV light source

Spectrophotometric Mode

Flat Grating

Sensor

Silicon photodiode array (double row 32 groups)

Wavelength Range

360~780nm

Wavelength Interval

10nm

Measured Reflectance Range

0-200%

Measuring Aperture

5 apertures: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm;LAV:1x3mm

Specular Component

SCI&SCE

Color Space

CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99,Munsell(C/2)

Color Difference Formula

ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)

Other Colorimetric Index

Spectral reflectance,WI(ASTM E313,CIE/ISO, AATCC, Hunter, TaubeBergerStensby),

YI(ASTM D1925,ASTM 313),

Metamerism Index MI,

Staining Fastness, Color Fastness, Color Strength, Opacity,

8° Glossiness,555 tone classification, Carbon (My,dM), color density CMYK(A,T,E,M), Tint, Munsel chroma index (part of the function is realized by PC software)

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30),B,U35,NBF, ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, able to customized light source (total 41 kinds of light source, Partially realize through the PC software /APP software)

Displayed Data

Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color simulation, Color Offset

Measuring Time

About 1.5s

Repeatability

Chromaticity value: MAV/SCI, within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%)

Inter-instrument Error

MAV/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles)

Display Resolution

0.01

Measurement Mode

Single Measurement, Average Measurement(2-99times)

Locating Method

Camera Locating,stabilizer cross position

Dimension

L*W*H=129X76X217mm

Weight

Approx 600g

Battery

Li-ion battery, 8800 measurements within 8 hours

Illuminant Life Span

10 years, more than 1.5 million times measurements

Displayed Data

3.5-inch TFT color LCD, Capacitive Touch Screen

Data Port

USB, Bluetooth ® 5.0

Data Storage

Standard 1000 Pcs, Sample 30000 Pcs, APP/PC mass storage

Software Support

Andriod,IOS,Windows,Harmony OS,Wechat applets

Language

Simplified Chinese, English, traditional Chinese

Operating Environment

0~40℃, 0~85%RH (no condensing), Altitude < 2000m

Storage Environment

-20~50℃, 0~85%RH (no condensing)

Standard Accessory

Power Adapter, USB cable, User Guide, PC Software(Download from office website), White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture,1x3mm tip aperture

Optional Accessory

Micro Printer, Powder Test Box

Notes

The specifications are subject to change without notice.

6-8/F,Building B33,Low-Carbon Headquarters Park,400 Xincheng Avenue,Zengcheng District,Guangzhou,P.R.China.