Model
|
YS6003
|
Optical Geometry
|
Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ; SCI (specular component included)/SCE (specular component excluded) ; ; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
|
Application
|
It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
|
Integrating Sphere Size
|
Φ154mm
|
Light Source
|
360 nm to 780 nm, Combined LED Light (5 million life span)
|
Spectrophotometric Mode
|
Concave Grating
|
Sensor
|
256 Image Element Double Array CMOS Image Sensor
|
Wavelength Range
|
360-780nm
|
Wavelength Interval
|
10nm
|
Semiband Width
|
10nm
|
Measured Reflectance Range
|
0-200%
|
Measuring Aperture
|
Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
|
Transmissive : Φ30mm/Φ25mm;
|
Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
|
Specular Component
|
Reflectance: SCI&SCE / Transmittance: SCI&SCE
|
Color Space
|
CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
|
Color Difference Formula
|
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
|
Other Colorimetric Index
|
WI (ASTM E313, CIE/ISO, AATCC, Hunter),
|
YI (ASTM D1925, ASTM 313),
|
TI (ASTM E313, CIE/ISO),
|
MI (Metamerism Index),
|
Staining Fastness, Color Fastness, Color Strength, Opacity,
|
8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
|
Observer Angle
|
2°/10°
|
Illuminant
|
D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
|
Displayed Data
|
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
|
Measuring Time
|
About 2.4s (Measure SCI & SCE about 5s)
|
Repeatability
|
Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.05%)
|
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.06%)
|
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
|
Inter-instrument Error
|
Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles)
|
Dimension
|
L*W*H=370x300x200mm
|
Weight
|
Approx. 9.6kg
|
Power
|
AC 24V, 3A Power adapter power supply
|
Illuminant Life Span
|
5 years, more than 3 million times measurements
|
Display
|
7-inch TFT color LCD, Capacitive Touch Screen
|
Data Port
|
USB & Print serial port
|
Data Storage
|
Standard 1000 Pcs, Sample 20000 Pcs
|
Language
|
Simplified Chinese, Traditional Chinese, English,
|
Operating Environment
|
0~40℃, 0~85%RH (no condensing), Altitude < 2000m
|
Storage Environment
|
-20~50℃, 0~85%RH (no condensing)
|
Standard Accessory
|
Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber
|
Optional Accessory
|
Micro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
|
Notes: The specifications are subject to change without notice. YS6003 quality management software can only be used for data management
|