You Are Here : Home >> Products >> Haze Meter >> YH1102 Haze Meter With 2 Apertures

YH1102 Haze Meter With 2 Apertures

YH1102 haze meter can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1102 haze meter uses a PD array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.
More Photos:
Date:2024-03-20  Browse:
  • Introduction
  • Product Software

YH1102 Haze Meter with Two Apertures

YH1102 haze meter can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1102 haze meter uses a PD array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.

Technical Advantage

1.Conforms to ASTM standards

Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,GB/T 2410, JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361, JIS K 7136

Conforms to ASTM standards

2.Easy to operate, faster and more accurate measurement

The YH1102 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and haze measurements.USB data output device for docking with laboratory system.

Easy to operate, faster and more accurate measurement

3.Dynamic measurement

Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.

Dynamic measurement

4.Easy to measure and widely applicable to samples

Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.

Easy to measure and widely applicable to samples

5.Quality control software

It provides powerful software for measuring and analyzing haze and light transmittance, which is suitable for quality monitoring and tabulated management of haze and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of haze and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.

Quality control software

Application

YH1102 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.

 

Technical Specification

Product Model  YH1102 Haze Meter
Optical Geometry Transmittance:0/D(Parallel light illumination, diffuse viewing);Conform to the standards:ASTM D1003/1044, ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136
Characteristic The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection.
Integrating Sphere Size Φ154mm
Light Source 400nm to 700nm, combined LED light
Spectrophotometric Mode /
Sensor The PD array detector, satisfies CIE V(λ)2 degree visual response
Wavelength Range /
Wavelength Interval /
Semiband Width /
Measurement range 0~100%
Measuring Aperture Φ20mm/Φ8mm(Dual Aperture)
Sample Size Thickness <170mm
Color Space /
Color Difference Formula /
Other Colorimetric Index Haze(ASTM D1003/1044),Transmittance T(ASTM)
Observer Angle
Illuminant D65,A,C
Displayed Data PASS/FAIL Result
Measuring Time About1.5s
Resolution 0.01unit
Repeatability Φ20mm,within 0.05(After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 30 for 30 times were taken at intervals of 5s.)
Inter-instrument Error Φ20mm,with 0.4(After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.)
Dimension L*W*H=290X211X511mm
Weight About7.6kg
Power AC 24V, 3A Power adapter power supply
Illuminant Life Span 5 years, more than 3 million times measurements
Display 7-inch TFT color LCD, Capacitive Touch Screen
Data Port USB, Print serial port
Data Storage Standard 1000 pcs,sample 20000 pcs
Language Simplified Chinese,Traditional Chinese,English
Operating Environment 0~40℃(32~104°F)
Storage Environment  -20~50℃(-4~122°F)
Standard Accessory Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture.
Optional Accessory Micro-printer,Test fixture, standard haze sheet, foot switch