Sineimage YE0256 COLOR AND CALIBRATION TEST CHART
Material | HD photographic paper/Film |
The Sineimage YE0256 COLOR AND CALIBRATION TEST CHART is designed to color align HD cameras.
Two 11-graduated counter current gray scales are arranged on a gray background (D≈0.62, remission=24%), the gray scale being graduated logarithmically. Related to the densities of the gray scales: gamma = 0.45, related to the remission values (brightness): gamma = 2.2, that being exactly the reciprocal value of 0.45.
The gamma factor 0.45 applies to remission > 1.8% (brightest step 100%). Between 0 and 1.8% the gamma function shows a linear progression (with the factor 4.5). The darkest step is in this area. The gamma function corresponds to Rec. 709. The output of an optimally gamma-corrected camera yields two 11-graduated counter current linear step signals (see figure below). The dynamic range of the gray scales is 63:1.
Field | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | BG |
Density | 0.05 | 0.14 | 0.23 | 0.33 | 0.45 | 0.58 | 0.73 | 0.91 | 1.14 | 1.43 | 1.85 | 0.62 |
The six color patches of the upper line represent the three primary colors red (R), green (G) and blue (B) as well as the three secondary colors cyan (C), magenta (M) and yellow (Y) according to the HDTV standard ITU-R BT.709 . Since it is impossible to depict the 100% saturated colors on a reflectance chart, the saturation is reduced to the maximum color space of the printer.
The six color patches of the lower line (yellow/green, blue, green, pink, red, magenta) represent the colors between the primary colors.
In addition to the gray scales and color patches for patches with skin tones are located.